Description
Box with Exd protection completed with weight indicator/transmitter, Zener barriers and intrinsically safe 4-20mA analog output. Fitted with 2 buttons for the main weighing operations with configurable functions, and two programmable electronic outputs for setpoints and levels management. Complete protection:
ATEX II 2 (1) GD Ex d [ia Ga] IIC T6 Gb / Ex tb [ia Da] IIIC T85°C Db IP66.
Technical features
- Aluminum alloy construction.
- Tempered glass, transparent, frontal porthole for weight reading and electronics checking.
- Painted with epoxy paint.
- 6 cable glands at disposal and standard fitted with 4 ATEX cable glands, for power supply, grounding, load cell cable and analog output.
- Weight: approx. 15kg.
- IP65 protection degree.
Indicator technical features
- DGT1SAN weight indicator with analog output, specific for the reading, diagnostic and transmission of the weight of one or more load cells.
- 5-key mechanic keyboard.
- Red LED display with 6 8-mm digits and 6 LEDs for showing active functions.
- Up to 10.000e or multi-range 2 x 3000e @ 0,3 µV/d in CE-M approved version for legal for trade use.
- Up to 100.000 displayable divisions with internal resolution up to 3.000.000 points.
- 1 channel A/D 24-bit sigma-delta conversion, up to 3200 conv./sec. auto-select.
- Fitted with 2 inputs for managing the buttons provided as standard and 2 programmable electronic outputs, for the set points and levels management.
Analog output technical features
- Intrinsically safe Ex barrier for 4-20mA analog output.
- Atex marking:
- II (1) GD [Ex ia Ga] IIC
- [Ex ia Da] IIIC (-20°C <= Ta <= +60°C)
- Ex i electronic parameters:
- Um=250V
- Uo= 25,2V
- Io= 93mA
- Po= 585mW
- Co= 0,107µF
- Lo= 4,30mH
- L/R= 62µH/ohm
Zener barries technical features
- The system includes 3 Zener barriers for load cells connection. The barriers can manage up to four 350Ohm load cells.
- Atex marking for one barrier:
- II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC
- Ex i electronic parameters:
- Barrier for signal and sense: Um=250V
- Fuse: 50mA
- Uo: 17,4V
- Io: 25mA
- Po: 0,11W
- Co: 0,346µF
- Lo: 56,88mH
- Rmin: 705,6Ohm
- Barrier for supply: Um=250V
- Fuse: 100mA
- Uo: 24V
- Io: 164mA
- Po: 0,98W
- Co: 0,125µF
- Lo: 1,32mH
- Rmin: 147Ohm