ATEX safe input/output in PW200XRD for DFWATEX2GDIO or DFWATEX2GDF
Description
- 4 data inputs (Exi inputs), with the following features (for interfacing with DFWATEXIO indicator):
- Ui: 40 Vdc
- Ii: 30 mA
- Li: 0 µH
- Ci: 0 µF - 4 intrinsically safe or unprotected data outputs (Exi inputs), with the following features (commanded by the DFWATEXIO indicator):
INTRINSIC SAFETY
- Ui: 40 Vdc
- Ii: 30 mA
- Li: 0 µH
- Ci: 0 µF
Note: If these inputs and outputs are powered through an intrinsic safety voltage inside the PW200XRD, the overall max. absorbable current from the 4 outputs and 4 inputs is 40mA; so, if just 1 output is used, it can supply up to 20mA
UNPROTECTED:
- Umax: 48 Vac o 60Vdc
- Imax: 150 mA
Documents
- Manual PW200XRD PW200XR V2.pdf Download
Is accesory to